| = sPAPR Dynamic Reconfiguration = |
| |
| sPAPR/"pseries" guests make use of a facility called dynamic-reconfiguration |
| to handle hotplugging of dynamic "physical" resources like PCI cards, or |
| "logical"/paravirtual resources like memory, CPUs, and "physical" |
| host-bridges, which are generally managed by the host/hypervisor and provided |
| to guests as virtualized resources. The specifics of dynamic-reconfiguration |
| are documented extensively in PAPR+ v2.7, Section 13.1. This document |
| provides a summary of that information as it applies to the implementation |
| within QEMU. |
| |
| == Dynamic-reconfiguration Connectors == |
| |
| To manage hotplug/unplug of these resources, a firmware abstraction known as |
| a Dynamic Resource Connector (DRC) is used to assign a particular dynamic |
| resource to the guest, and provide an interface for the guest to manage |
| configuration/removal of the resource associated with it. |
| |
| == Device-tree description of DRCs == |
| |
| A set of 4 Open Firmware device tree array properties are used to describe |
| the name/index/power-domain/type of each DRC allocated to a guest at |
| boot-time. There may be multiple sets of these arrays, rooted at different |
| paths in the device tree depending on the type of resource the DRCs manage. |
| |
| In some cases, the DRCs themselves may be provided by a dynamic resource, |
| such as the DRCs managing PCI slots on a hotplugged PHB. In this case the |
| arrays would be fetched as part of the device tree retrieval interfaces |
| for hotplugged resources described under "Guest->Host interface". |
| |
| The array properties are described below. Each entry/element in an array |
| describes the DRC identified by the element in the corresponding position |
| of ibm,drc-indexes: |
| |
| ibm,drc-names: |
| first 4-bytes: BE-encoded integer denoting the number of entries |
| each entry: a NULL-terminated <name> string encoded as a byte array |
| |
| <name> values for logical/virtual resources are defined in PAPR+ v2.7, |
| Section 13.5.2.4, and basically consist of the type of the resource |
| followed by a space and a numerical value that's unique across resources |
| of that type. |
| |
| <name> values for "physical" resources such as PCI or VIO devices are |
| defined as being "location codes", which are the "location labels" of |
| each encapsulating device, starting from the chassis down to the |
| individual slot for the device, concatenated by a hyphen. This provides |
| a mapping of resources to a physical location in a chassis for debugging |
| purposes. For QEMU, this mapping is less important, so we assign a |
| location code that conforms to naming specifications, but is simply a |
| location label for the slot by itself to simplify the implementation. |
| The naming convention for location labels is documented in detail in |
| PAPR+ v2.7, Section 12.3.1.5, and in our case amounts to using "C<n>" |
| for PCI/VIO device slots, where <n> is unique across all PCI/VIO |
| device slots. |
| |
| ibm,drc-indexes: |
| first 4-bytes: BE-encoded integer denoting the number of entries |
| each 4-byte entry: BE-encoded <index> integer that is unique across all DRCs |
| in the machine |
| |
| <index> is arbitrary, but in the case of QEMU we try to maintain the |
| convention used to assign them to pSeries guests on pHyp: |
| |
| bit[31:28]: integer encoding of <type>, where <type> is: |
| 1 for CPU resource |
| 2 for PHB resource |
| 3 for VIO resource |
| 4 for PCI resource |
| 8 for Memory resource |
| bit[27:0]: integer encoding of <id>, where <id> is unique across |
| all resources of specified type |
| |
| ibm,drc-power-domains: |
| first 4-bytes: BE-encoded integer denoting the number of entries |
| each 4-byte entry: 32-bit, BE-encoded <index> integer that specifies the |
| power domain the resource will be assigned to. In the case of QEMU |
| we associated all resources with a "live insertion" domain, where the |
| power is assumed to be managed automatically. The integer value for |
| this domain is a special value of -1. |
| |
| |
| ibm,drc-types: |
| first 4-bytes: BE-encoded integer denoting the number of entries |
| each entry: a NULL-terminated <type> string encoded as a byte array |
| |
| <type> is assigned as follows: |
| "CPU" for a CPU |
| "PHB" for a physical host-bridge |
| "SLOT" for a VIO slot |
| "28" for a PCI slot |
| "MEM" for memory resource |
| |
| == Guest->Host interface to manage dynamic resources == |
| |
| Each DRC is given a globally unique DRC Index, and resources associated with |
| a particular DRC are configured/managed by the guest via a number of RTAS |
| calls which reference individual DRCs based on the DRC index. This can be |
| considered the guest->host interface. |
| |
| rtas-set-power-level: |
| arg[0]: integer identifying power domain |
| arg[1]: new power level for the domain, 0-100 |
| output[0]: status, 0 on success |
| output[1]: power level after command |
| |
| Set the power level for a specified power domain |
| |
| rtas-get-power-level: |
| arg[0]: integer identifying power domain |
| output[0]: status, 0 on success |
| output[1]: current power level |
| |
| Get the power level for a specified power domain |
| |
| rtas-set-indicator: |
| arg[0]: integer identifying sensor/indicator type |
| arg[1]: index of sensor, for DR-related sensors this is generally the |
| DRC index |
| arg[2]: desired sensor value |
| output[0]: status, 0 on success |
| |
| Set the state of an indicator or sensor. For the purpose of this document we |
| focus on the indicator/sensor types associated with a DRC. The types are: |
| |
| 9001: isolation-state, controls/indicates whether a device has been made |
| accessible to a guest |
| |
| supported sensor values: |
| 0: isolate, device is made unaccessible by guest OS |
| 1: unisolate, device is made available to guest OS |
| |
| 9002: dr-indicator, controls "visual" indicator associated with device |
| |
| supported sensor values: |
| 0: inactive, resource may be safely removed |
| 1: active, resource is in use and cannot be safely removed |
| 2: identify, used to visually identify slot for interactive hotplug |
| 3: action, in most cases, used in the same manner as identify |
| |
| 9003: allocation-state, generally only used for "logical" DR resources to |
| request the allocation/deallocation of a resource prior to acquiring |
| it via isolation-state->unisolate, or after releasing it via |
| isolation-state->isolate, respectively. for "physical" DR (like PCI |
| hotplug/unplug) the pre-allocation of the resource is implied and |
| this sensor is unused. |
| |
| supported sensor values: |
| 0: unusable, tell firmware/system the resource can be |
| unallocated/reclaimed and added back to the system resource pool |
| 1: usable, request the resource be allocated/reserved for use by |
| guest OS |
| 2: exchange, used to allocate a spare resource to use for fail-over |
| in certain situations. unused in QEMU |
| 3: recover, used to reclaim a previously allocated resource that's |
| not currently allocated to the guest OS. unused in QEMU |
| |
| rtas-get-sensor-state: |
| arg[0]: integer identifying sensor/indicator type |
| arg[1]: index of sensor, for DR-related sensors this is generally the |
| DRC index |
| output[0]: status, 0 on success |
| |
| Used to read an indicator or sensor value. |
| |
| For DR-related operations, the only noteworthy sensor is dr-entity-sense, |
| which has a type value of 9003, as allocation-state does in the case of |
| rtas-set-indicator. The semantics/encodings of the sensor values are distinct |
| however: |
| |
| supported sensor values for dr-entity-sense (9003) sensor: |
| 0: empty, |
| for physical resources: DRC/slot is empty |
| for logical resources: unused |
| 1: present, |
| for physical resources: DRC/slot is populated with a device/resource |
| for logical resources: resource has been allocated to the DRC |
| 2: unusable, |
| for physical resources: unused |
| for logical resources: DRC has no resource allocated to it |
| 3: exchange, |
| for physical resources: unused |
| for logical resources: resource available for exchange (see |
| allocation-state sensor semantics above) |
| 4: recovery, |
| for physical resources: unused |
| for logical resources: resource available for recovery (see |
| allocation-state sensor semantics above) |
| |
| rtas-ibm-configure-connector: |
| arg[0]: guest physical address of 4096-byte work area buffer |
| arg[1]: 0, or address of additional 4096-byte work area buffer. only non-zero |
| if a prior RTAS response indicated a need for additional memory |
| output[0]: status: |
| 0: completed transmittal of device-tree node |
| 1: instruct guest to prepare for next DT sibling node |
| 2: instruct guest to prepare for next DT child node |
| 3: instruct guest to prepare for next DT property |
| 4: instruct guest to ascend to parent DT node |
| 5: instruct guest to provide additional work-area buffer |
| via arg[1] |
| 990x: instruct guest that operation took too long and to try |
| again later |
| |
| Used to fetch an OF device-tree description of the resource associated with |
| a particular DRC. The DRC index is encoded in the first 4-bytes of the first |
| work area buffer. |
| |
| Work area layout, using 4-byte offsets: |
| wa[0]: DRC index of the DRC to fetch device-tree nodes from |
| wa[1]: 0 (hard-coded) |
| wa[2]: for next-sibling/next-child response: |
| wa offset of null-terminated string denoting the new node's name |
| for next-property response: |
| wa offset of null-terminated string denoting new property's name |
| wa[3]: for next-property response (unused otherwise): |
| byte-length of new property's value |
| wa[4]: for next-property response (unused otherwise): |
| new property's value, encoded as an OFDT-compatible byte array |
| |
| == hotplug/unplug events == |
| |
| For most DR operations, the hypervisor will issue host->guest add/remove events |
| using the EPOW/check-exception notification framework, where the host issues a |
| check-exception interrupt, then provides an RTAS event log via an |
| rtas-check-exception call issued by the guest in response. This framework is |
| documented by PAPR+ v2.7, and already use in by QEMU for generating powerdown |
| requests via EPOW events. |
| |
| For DR, this framework has been extended to include hotplug events, which were |
| previously unneeded due to direct manipulation of DR-related guest userspace |
| tools by host-level management such as an HMC. This level of management is not |
| applicable to PowerKVM, hence the reason for extending the notification |
| framework to support hotplug events. |
| |
| The format for these EPOW-signalled events is described below under |
| "hotplug/unplug event structure". Note that these events are not |
| formally part of the PAPR+ specification, and have been superseded by a |
| newer format, also described below under "hotplug/unplug event structure", |
| and so are now deemed a "legacy" format. The formats are similar, but the |
| "modern" format contains additional fields/flags, which are denoted for the |
| purposes of this documentation with "#ifdef GUEST_SUPPORTS_MODERN" guards. |
| |
| QEMU should assume support only for "legacy" fields/flags unless the guest |
| advertises support for the "modern" format via ibm,client-architecture-support |
| hcall by setting byte 5, bit 6 of it's ibm,architecture-vec-5 option vector |
| structure (as described by LoPAPR v11, B.6.2.3). As with "legacy" format events, |
| "modern" format events are surfaced to the guest via check-exception RTAS calls, |
| but use a dedicated event source to signal the guest. This event source is |
| advertised to the guest by the addition of a "hot-plug-events" node under |
| "/event-sources" node of the guest's device tree using the standard format |
| described in LoPAPR v11, B.6.12.1. |
| |
| == hotplug/unplug event structure == |
| |
| The hotplug-specific payload in QEMU is implemented as follows (with all values |
| encoded in big-endian format): |
| |
| struct rtas_event_log_v6_hp { |
| #define SECTION_ID_HOTPLUG 0x4850 /* HP */ |
| struct section_header { |
| uint16_t section_id; /* set to SECTION_ID_HOTPLUG */ |
| uint16_t section_length; /* sizeof(rtas_event_log_v6_hp), |
| * plus the length of the DRC name |
| * if a DRC name identifier is |
| * specified for hotplug_identifier |
| */ |
| uint8_t section_version; /* version 1 */ |
| uint8_t section_subtype; /* unused */ |
| uint16_t creator_component_id; /* unused */ |
| } hdr; |
| #define RTAS_LOG_V6_HP_TYPE_CPU 1 |
| #define RTAS_LOG_V6_HP_TYPE_MEMORY 2 |
| #define RTAS_LOG_V6_HP_TYPE_SLOT 3 |
| #define RTAS_LOG_V6_HP_TYPE_PHB 4 |
| #define RTAS_LOG_V6_HP_TYPE_PCI 5 |
| uint8_t hotplug_type; /* type of resource/device */ |
| #define RTAS_LOG_V6_HP_ACTION_ADD 1 |
| #define RTAS_LOG_V6_HP_ACTION_REMOVE 2 |
| uint8_t hotplug_action; /* action (add/remove) */ |
| #define RTAS_LOG_V6_HP_ID_DRC_NAME 1 |
| #define RTAS_LOG_V6_HP_ID_DRC_INDEX 2 |
| #define RTAS_LOG_V6_HP_ID_DRC_COUNT 3 |
| #ifdef GUEST_SUPPORTS_MODERN |
| #define RTAS_LOG_V6_HP_ID_DRC_COUNT_INDEXED 4 |
| #endif |
| uint8_t hotplug_identifier; /* type of the resource identifier, |
| * which serves as the discriminator |
| * for the 'drc' union field below |
| */ |
| #ifdef GUEST_SUPPORTS_MODERN |
| uint8_t capabilities; /* capability flags, currently unused |
| * by QEMU |
| */ |
| #else |
| uint8_t reserved; |
| #endif |
| union { |
| uint32_t index; /* DRC index of resource to take action |
| * on |
| */ |
| uint32_t count; /* number of DR resources to take |
| * action on (guest chooses which) |
| */ |
| #ifdef GUEST_SUPPORTS_MODERN |
| struct { |
| uint32_t count; /* number of DR resources to take |
| * action on |
| */ |
| uint32_t index; /* DRC index of first resource to take |
| * action on. guest will take action |
| * on DRC index <index> through |
| * DRC index <index + count - 1> in |
| * sequential order |
| */ |
| } count_indexed; |
| #endif |
| char name[1]; /* string representing the name of the |
| * DRC to take action on |
| */ |
| } drc; |
| } QEMU_PACKED; |
| |
| == ibm,lrdr-capacity == |
| |
| ibm,lrdr-capacity is a property in the /rtas device tree node that identifies |
| the dynamic reconfiguration capabilities of the guest. It consists of a triple |
| consisting of <phys>, <size> and <maxcpus>. |
| |
| <phys>, encoded in BE format represents the maximum address in bytes and |
| hence the maximum memory that can be allocated to the guest. |
| |
| <size>, encoded in BE format represents the size increments in which |
| memory can be hot-plugged to the guest. |
| |
| <maxcpus>, a BE-encoded integer, represents the maximum number of |
| processors that the guest can have. |
| |
| pseries guests use this property to note the maximum allowed CPUs for the |
| guest. |
| |
| == ibm,dynamic-reconfiguration-memory == |
| |
| ibm,dynamic-reconfiguration-memory is a device tree node that represents |
| dynamically reconfigurable logical memory blocks (LMB). This node |
| is generated only when the guest advertises the support for it via |
| ibm,client-architecture-support call. Memory that is not dynamically |
| reconfigurable is represented by /memory nodes. The properties of this |
| node that are of interest to the sPAPR memory hotplug implementation |
| in QEMU are described here. |
| |
| ibm,lmb-size |
| |
| This 64bit integer defines the size of each dynamically reconfigurable LMB. |
| |
| ibm,associativity-lookup-arrays |
| |
| This property defines a lookup array in which the NUMA associativity |
| information for each LMB can be found. It is a property encoded array |
| that begins with an integer M, the number of associativity lists followed |
| by an integer N, the number of entries per associativity list and terminated |
| by M associativity lists each of length N integers. |
| |
| This property provides the same information as given by ibm,associativity |
| property in a /memory node. Each assigned LMB has an index value between |
| 0 and M-1 which is used as an index into this table to select which |
| associativity list to use for the LMB. This index value for each LMB |
| is defined in ibm,dynamic-memory property. |
| |
| ibm,dynamic-memory |
| |
| This property describes the dynamically reconfigurable memory. It is a |
| property encoded array that has an integer N, the number of LMBs followed |
| by N LMB list entires. |
| |
| Each LMB list entry consists of the following elements: |
| |
| - Logical address of the start of the LMB encoded as a 64bit integer. This |
| corresponds to reg property in /memory node. |
| - DRC index of the LMB that corresponds to ibm,my-drc-index property |
| in a /memory node. |
| - Four bytes reserved for expansion. |
| - Associativity list index for the LMB that is used as an index into |
| ibm,associativity-lookup-arrays property described earlier. This |
| is used to retrieve the right associativity list to be used for this |
| LMB. |
| - A 32bit flags word. The bit at bit position 0x00000008 defines whether |
| the LMB is assigned to the partition as of boot time. |
| |
| ibm,dynamic-memory-v2 |
| |
| This property describes the dynamically reconfigurable memory. This is |
| an alternate and newer way to describe dyanamically reconfigurable memory. |
| It is a property encoded array that has an integer N (the number of |
| LMB set entries) followed by N LMB set entries. There is an LMB set entry |
| for each sequential group of LMBs that share common attributes. |
| |
| Each LMB set entry consists of the following elements: |
| |
| - Number of sequential LMBs in the entry represented by a 32bit integer. |
| - Logical address of the first LMB in the set encoded as a 64bit integer. |
| - DRC index of the first LMB in the set. |
| - Associativity list index that is used as an index into |
| ibm,associativity-lookup-arrays property described earlier. This |
| is used to retrieve the right associativity list to be used for all |
| the LMBs in this set. |
| - A 32bit flags word that applies to all the LMBs in the set. |
| |
| [1] http://thread.gmane.org/gmane.linux.ports.ppc.embedded/75350/focus=106867 |