| \ * Copyright (c) 2004, 2008 IBM Corporation |
| \ * All rights reserved. |
| \ * This program and the accompanying materials |
| \ * are made available under the terms of the BSD License |
| \ * which accompanies this distribution, and is available at |
| \ * http://www.opensource.org/licenses/bsd-license.php |
| \ * |
| \ * Contributors: |
| \ * IBM Corporation - initial implementation |
| \ ****************************************************************************/ |
| |
| \ Set by update-flash -f to true, preventing update-flash -c |
| false value flash-new |
| |
| : update-flash-help ( -- ) |
| cr ." update-flash tool to flash host FW " cr |
| ." -f <filename> : Flash from file (e.g. net:\boot_rom.bin)" cr |
| ." -l : Flash from load-base" cr |
| ." -d : Flash from old load base (used by drone)" cr |
| ." -c : Flash from temp to perm" cr |
| ." -r : Flash from perm to temp" cr |
| ; |
| |
| : flash-read-temp ( -- success? ) |
| get-flashside 1 = IF flash-addr load-base over flash-image-size rmove true |
| ELSE |
| false |
| THEN |
| ; |
| |
| : flash-read-perm ( -- success? ) |
| get-flashside 0= IF |
| flash-addr load-base over flash-image-size rmove true |
| ELSE |
| false |
| THEN |
| ; |
| |
| : flash-switch-side ( side -- success? ) |
| set-flashside 0<> IF |
| s" Cannot change flashside" type cr false |
| ELSE |
| true |
| THEN |
| ; |
| |
| : flash-ensure-temp ( -- success? ) |
| get-flashside 0= IF |
| cr ." Cannot flash perm! Switching to temp side!" |
| 1 flash-switch-side |
| ELSE |
| true |
| THEN |
| ; |
| |
| \ update-flash -f <filename> |
| \ -l |
| \ -c |
| \ -r |
| |
| : update-flash ( "text" ) |
| get-flashside >r \ Save old flashside |
| parse-word ( str len ) \ Parse first string |
| drop dup c@ ( str first-char ) |
| [char] - <> IF |
| update-flash-help r> 2drop EXIT |
| THEN |
| |
| 1+ c@ ( second-char ) |
| CASE |
| [char] f OF |
| parse-word cr s" do-load" evaluate |
| flash-ensure-temp TO flash-new |
| ENDOF |
| [char] l OF |
| flash-ensure-temp |
| ENDOF |
| [char] d OF |
| flash-load-base load-base 200000 move |
| flash-ensure-temp |
| ENDOF |
| [char] c OF |
| flash-read-temp 0= flash-new or IF |
| ." Cannot commit temp, need to boot on temp first " cr false |
| ELSE |
| 0 flash-switch-side |
| THEN |
| ENDOF |
| [char] r OF |
| flash-read-perm 0= IF |
| ." Cannot commit perm, need to boot on perm first " cr false |
| ELSE |
| 1 flash-switch-side |
| THEN |
| ENDOF |
| dup OF |
| false |
| ENDOF |
| ENDCASE |
| |
| ( true| false ) |
| |
| 0= IF |
| update-flash-help r> drop EXIT |
| THEN |
| |
| load-base flash-write 0= IF ." Flash write failed !! " cr THEN |
| r> set-flashside drop \ Restore old flashside |
| ; |