  "commit": "f2d189d38436a8ccdedd94de01673b04aa008e11",
  "tree": "7fe289b1116341c3193f508b6c345e1e03b23ecf",
  "parents": [
    "fc5b64d0829297c7a525ddf6c0bb08ef0a9af5b6"
  ],
  "author": {
    "name": "Igor Mitsyanko",
    "email": "i.mitsyanko@gmail.com",
    "time": "Tue Oct 30 07:45:12 2012 +0000"
  },
  "committer": {
    "name": "Peter Maydell",
    "email": "peter.maydell@linaro.org",
    "time": "Tue Oct 30 07:45:12 2012 +0000"
  },
  "message": "hw/sd.c: Fix erase for high capacity cards\n\nStandard capacity cards SDSC use byte unit address while SDHC and SDXC cards use\nblock unit address (512 bytes) when setting ERASE_START and ERASE_END with CMD32\nand CMD33, we have to account for this.\n\nSigned-off-by: Igor Mitsyanko \u003ci.mitsyanko@samsung.com\u003e\nReviewed-by: Peter Maydell \u003cpeter.maydell@linaro.org\u003e\nSigned-off-by: Peter Maydell \u003cpeter.maydell@linaro.org\u003e\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "297580aabefdb014a1a4590a5f8d326148ba2391",
      "old_mode": 33188,
      "old_path": "hw/sd.c",
      "new_id": "b2f211c13ab97dc78b6aef12353cff9a0c6281fd",
      "new_mode": 33188,
      "new_path": "hw/sd.c"
    },
    {
      "type": "modify",
      "old_id": "4eb9679acd89739b8b159aa513c8b9ce8262f9ef",
      "old_mode": 33188,
      "old_path": "hw/sd.h",
      "new_id": "d9b97e44664bc2bb621b7e7556f0af74c015e8af",
      "new_mode": 33188,
      "new_path": "hw/sd.h"
    }
  ]
}