target/riscv: Start counters from both mhpmcounter and mcountinhibit

Currently we start timer counter from write_mhpmcounter path only
without checking for mcountinhibit bit. This changes adds mcountinhibit
check and also programs the counter from write_mcountinhibit as well.

When a counter is stopped using mcountinhibit we simply update
the value of the counter based on current host ticks and save
it for future reads.

We don't need to disable running timer as pmu_timer_trigger_irq
will discard the interrupt if the counter has been inhibited.

Signed-off-by: Rajnesh Kanwal <rkanwal@rivosinc.com>
Reviewed-by: Daniel Henrique Barboza <dbarboza@ventanamicro.com>
Message-ID: <20240711-smcntrpmf_v7-v8-10-b7c38ae7b263@rivosinc.com>
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
2 files changed