hw/arm/smmuv3: Check stream IDs against actual table LOG2SIZE

When checking whether a stream ID is in range of the stream table, we
have so far been only checking it against our implementation limit
(SMMU_IDR1_SIDSIZE). However, the guest can program the
STRTAB_BASE_CFG.LOG2SIZE field to a size that is smaller than this
limit.

Check the stream ID against this limit as well to match the hardware
behavior of raising C_BAD_STREAMID events in case the limit is exceeded.
Also, ensure that we do not go one entry beyond the end of the table by
checking that its index is strictly smaller than the table size.

ref. ARM IHI 0070C, section 6.3.24.

Signed-off-by: Simon Veith <sveith@amazon.de>
Acked-by: Eric Auger <eric.auger@redhat.com>
Tested-by: Eric Auger <eric.auger@redhat.com>
Message-id: 1576509312-13083-4-git-send-email-sveith@amazon.de
Cc: Eric Auger <eric.auger@redhat.com>
Cc: qemu-devel@nongnu.org
Cc: qemu-arm@nongnu.org
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
1 file changed