  "commit": "83ed48b87bab16f0eb35d08b351ecb8a3f13f0b6",
  "tree": "6088bf3b4aefc4abf7c44b2675323e75317f5ea3",
  "parents": [
    "281eb77348aa13a8e8c15df7fdaf31b080e67376"
  ],
  "author": {
    "name": "Gary Beihl",
    "email": "garybeihl@microsoft.com",
    "time": "Mon Jan 05 19:15:13 2026 +0100"
  },
  "committer": {
    "name": "Samuel Thibault",
    "email": "samuel.thibault@ens-lyon.org",
    "time": "Mon Jan 05 19:19:05 2026 +0100"
  },
  "message": "ncsi: Document why we fix memory alignment by adding 2-byte padding\n\nbefore the Ethernet header. This ensures the IP payload starts on a 4-byte\nboundary, which reduces packet processing errors by ~50% and resolves the\n\"NCSI: Handler for packet type 0x82 returned -19\" errors seen during channel\ninitialization on some architectures.\n\nSigned-off-by: Gary Beihl \u003cgarybeihl@microsoft.com\u003e\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "0509eafaa4f2883a0bd3abb4cea5e4d3cdd7e8f4",
      "old_mode": 33188,
      "old_path": "src/ncsi.c",
      "new_id": "c10b0dfe34d9350bf1679cb8e0ab3e61ed2fff85",
      "new_mode": 33188,
      "new_path": "src/ncsi.c"
    }
  ]
}